How critical is spray distance in your HVOF process?
With SprayWatch, you can easily measure particle velocity and temperature at different spraying distances and see how these parameters change.
These measurements help you understand how sensitive your process is to spray distance and anticipate how changes in distance might affect coating quality.
Find a working distance that suits your process
Start with two spraying distances and keep the other process settings the same. At each distance, measure particle velocity and temperature just before the particles reach the surface. Then compare the readings alongside the coatings produced in the two runs.
Seeing how the particles arrive gives you more information to work with when choosing a working distance or deciding how tightly to control it in production.